CCZTC - 55413 DEG00 QUANTIKINE HUMAN EGF IMMUNOASSAY

  • MSDS: CCZTC
  • Manufacturer: R AND D SYSTEMS INC
  • Product Name: 55413 DEG00 QUANTIKINE HUMAN EGF IMMUNOASSAY
  • National Stock Number: 6550-00F051971
Product Identification

Product ID:55413 DEG00 QUANTIKINE HUMAN EGF IMMUNOASSAY
MSDS Date:03/31/1995
FSC:6550
NIIN:00F051971
MSDS Number: CCZTC

Responsible Party
R & D SYSTEMS INC
614 MCKINLEY PLACE NE
MINNEAPOLIS, MN 55413-5000
US

Emergency Phone: 612-379-2956/800-343-7475

Info Phone: 612-379-2956/800-343-7475

Cage: GO444

Contractor
R AND D SYSTEMS INC
MINNEAPOLIS, MN 55413-5000 US

Telephone: 612-379-2956

Cage: 6S541

Ingredients

SULFURIC ACID (CONFIRMED HUMAN CARCINOGEN BY IARC - GROUP

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 5.56%

OSHA PEL 1 MG/CUM

ACGIH TLV: 1 MG/CUM=IC

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYES: MAY CAUSE SEVERE
IRRITATION/BURNS. INHALATION: IRRITATING TO NOSE & THROAT.
INGESTION: POISON, MAY BE FATAL & CAUSE BURNS.
Explanation of Carcinogenicity:SEE INGREDIENTS.
Effects of Overexposure:IRRITATION, BURNS.

First Aid

First Aid:INGESTION: DON'T INDUCE VOMITING; IF CONSCIOUS, GIVE WATER,
MILK/MILK OF MAGNESIA. EYES/SKIN: FLUSH W/PLENTY OF WATER FOR 15
MINS. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:DRY CHEMICAL/CO2.
Fire Fighting Procedures:DON'T USE WATER.

Accidental Release

Spill Release Procedures:NEUTRALIZE W/SODA ASH/LIME. CAREFULLY PLACE
MATERIAL INTO A CONTROL CONTAINER & REMOVE FROM THE AREA. FLUSH
AREA W/WATER.
Neutralizing Agent:SODA ASH/LIME.

Handling

Handling and Storage Precautions:KEEP IN TIGHTLY CLOSED CONTAINER.
STORE SEPARATELY & AWAY FROM FLAMMABLES & COMBUSTIBLE MATERIALS.
Other Precautions:DON'T GET IN EYES, SKIN/CLOTHING. DON'T BREATH VAPOR.

Exposure Controls

Respiratory Protection:THIS IS A LABORATORY USE PRODUCT FOR WHICH NO
INDUSTRIAL PROTECTIVE EQUIPMENT HAS BEEN DESIGNATED.
Ventilation:USE W/ADEQUATE VENTILATION.
Protective Gloves:LATEX
Eye Protection:SAFETY GLASSES
Other Protective Equipment:LAB COAT & APRON.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING & SHOES
BEFORE REUSE. WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health

Chemical Properties

Appearance and Odor:CLEAR LIQUID, COLORLESS SOLUTION

Stability

Stability Indicator/Materials to Avoid:YES
WATER & STRONG BASES.

Disposal

Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.